Class BarcodeFormatCode2Of5Configuration

  • All Implemented Interfaces:
    android.os.Parcelable

    public final class BarcodeFormatCode2Of5Configuration
    extends BarcodeFormatOneDConfigurationBase implements Parcelable
                        

    Configuration for all 2-of-5 barcode types (except Interleaved 2-of-5, which is handled by ItfConfig). Add to scanner configuration to scan Code 25, IATA 2-of-5 and Industrial 2-of-5 barcodes.

    Industrial 2-of-5 barcodes are a subset of Code 25 barcodes. Any valid Industrial 2-of-5 barcode is also a valid Code 25 barcode.

    • Constructor Detail

      • BarcodeFormatCode2Of5Configuration

        BarcodeFormatCode2Of5Configuration(Map<String, Object> source)
      • BarcodeFormatCode2Of5Configuration

        BarcodeFormatCode2Of5Configuration(JSONObject json)
    • Method Detail

      • getRegexFilter

         String getRegexFilter()

        Regular expression filter for barcode text. If the barcode text does not match the regular expression, it will not be scanned. The default is an empty string (setting is turned off).

        Default is ""

      • setRegexFilter

         Unit setRegexFilter(String regexFilter)

        Regular expression filter for barcode text. If the barcode text does not match the regular expression, it will not be scanned. The default is an empty string (setting is turned off).

        Default is ""

      • getMinimumSizeScore

         Double getMinimumSizeScore()

        Minimum acceptable value of a result BarcodeItem's sizeScore (between 0 and 1). Barcodes with a sizeScore less than this value will not be scanned. When set to 0, barcodes are returned no matter what their size is.

        Default is 0

      • setMinimumSizeScore

         Unit setMinimumSizeScore(Double minimumSizeScore)

        Minimum acceptable value of a result BarcodeItem's sizeScore (between 0 and 1). Barcodes with a sizeScore less than this value will not be scanned. When set to 0, barcodes are returned no matter what their size is.

        Default is 0

      • getAddAdditionalQuietZone

         Boolean getAddAdditionalQuietZone()

        If true, we process the barcode scanning with an artificial quiet zone that we add to the input image. This flag should be used to scan sharp crops of a barcode in single-shot mode.

        Default is false

      • setAddAdditionalQuietZone

         Unit setAddAdditionalQuietZone(Boolean addAdditionalQuietZone)

        If true, we process the barcode scanning with an artificial quiet zone that we add to the input image. This flag should be used to scan sharp crops of a barcode in single-shot mode.

        Default is false

      • getMinimum1DQuietZoneSize

         Integer getMinimum1DQuietZoneSize()

        Minimum quiet zone size on the left and right sides of a 1D barcode, measured in number of modules. The quiet zone is only for 1D barcodes with weak start/stop patterns, i.e. Iata2Of5, Industrial2Of5, Code25, Itf, Codabar, MsiPlessey, and Code11.

        Default is 6

      • setMinimum1DQuietZoneSize

         Unit setMinimum1DQuietZoneSize(Integer minimum1DQuietZoneSize)

        Minimum quiet zone size on the left and right sides of a 1D barcode, measured in number of modules. The quiet zone is only for 1D barcodes with weak start/stop patterns, i.e. Iata2Of5, Industrial2Of5, Code25, Itf, Codabar, MsiPlessey, and Code11.

        Default is 6

      • setStripCheckDigits

         final Unit setStripCheckDigits(Boolean stripCheckDigits)

        If true, the check digits are stripped from the result.

        Default is false

      • getMinimumTextLength

         final Integer getMinimumTextLength()

        Minimum text length. Applied only to linear barcode formats that allow variable length.

        Default is 1

      • setMinimumTextLength

         final Unit setMinimumTextLength(Integer minimumTextLength)

        Minimum text length. Applied only to linear barcode formats that allow variable length.

        Default is 1

      • getMaximumTextLength

         final Integer getMaximumTextLength()

        Maximum text length. 0 implies no maximum. Applied only to linear barcode formats that allow variable length.

        Default is 0

      • setMaximumTextLength

         final Unit setMaximumTextLength(Integer maximumTextLength)

        Maximum text length. 0 implies no maximum. Applied only to linear barcode formats that allow variable length.

        Default is 0

      • getIata2of5

         final Boolean getIata2of5()

        If true, scan IATA 2-of-5 barcodes. If useIATA2OF5Checksum is true, only barcodes with a valid checksum are returned.

        Default is true

      • setIata2of5

         final Unit setIata2of5(Boolean iata2of5)

        If true, scan IATA 2-of-5 barcodes. If useIATA2OF5Checksum is true, only barcodes with a valid checksum are returned.

        Default is true

      • getCode25

         final Boolean getCode25()

        If true, scan and return Code 25 (Code 2-of-5) barcodes. If industrial2of5 is also true, then valid Industrial 2-of-5 barcodes will preferentially be returned as such, instead of Code 25.

        Default is false

      • setCode25

         final Unit setCode25(Boolean code25)

        If true, scan and return Code 25 (Code 2-of-5) barcodes. If industrial2of5 is also true, then valid Industrial 2-of-5 barcodes will preferentially be returned as such, instead of Code 25.

        Default is false

      • getIndustrial2of5

         final Boolean getIndustrial2of5()

        If true, scan and return valid Industrial 2-of-5 barcodes. If false, but code25 is true, Industrial 2-of-5 barcodes will be returned as Code 25 barcodes.

        Default is true

      • setIndustrial2of5

         final Unit setIndustrial2of5(Boolean industrial2of5)

        If true, scan and return valid Industrial 2-of-5 barcodes. If false, but code25 is true, Industrial 2-of-5 barcodes will be returned as Code 25 barcodes.

        Default is true

      • getUseIATA2OF5Checksum

         final Boolean getUseIATA2OF5Checksum()

        If true, return IATA_2_OF_5 barcodes only if they have a valid check digit.

        Default is true

      • setUseIATA2OF5Checksum

         final Unit setUseIATA2OF5Checksum(Boolean useIATA2OF5Checksum)

        If true, return IATA_2_OF_5 barcodes only if they have a valid check digit.

        Default is true