Class BarcodeFormatUpcEanConfiguration

    • Method Detail

      • getRegexFilter

         String getRegexFilter()

        Regular expression filter for barcode text. If the barcode text does not match the regular expression, it will not be scanned. The default is an empty string (setting is turned off).

        Default is ""

      • setRegexFilter

         Unit setRegexFilter(String regexFilter)

        Regular expression filter for barcode text. If the barcode text does not match the regular expression, it will not be scanned. The default is an empty string (setting is turned off).

        Default is ""

      • getMinimumSizeScore

         Double getMinimumSizeScore()

        Minimum acceptable value of a result BarcodeItem's sizeScore (between 0 and 1). Barcodes with a sizeScore less than this value will not be scanned. When set to 0, barcodes are returned no matter what their size is.

        Default is 0

      • setMinimumSizeScore

         Unit setMinimumSizeScore(Double minimumSizeScore)

        Minimum acceptable value of a result BarcodeItem's sizeScore (between 0 and 1). Barcodes with a sizeScore less than this value will not be scanned. When set to 0, barcodes are returned no matter what their size is.

        Default is 0

      • getAddAdditionalQuietZone

         Boolean getAddAdditionalQuietZone()

        If true, we process the barcode scanning with an artificial quiet zone that we add to the input image. This flag should be used to scan sharp crops of a barcode in single-shot mode.

        Default is false

      • setAddAdditionalQuietZone

         Unit setAddAdditionalQuietZone(Boolean addAdditionalQuietZone)

        If true, we process the barcode scanning with an artificial quiet zone that we add to the input image. This flag should be used to scan sharp crops of a barcode in single-shot mode.

        Default is false

      • getMinimum1DQuietZoneSize

         Integer getMinimum1DQuietZoneSize()

        Minimum quiet zone size on the left and right sides of a 1D barcode, measured in number of modules. The quiet zone is only for 1D barcodes with weak start/stop patterns, i.e. Iata2Of5, Industrial2Of5, Code25, Itf, Codabar, MsiPlessey, and Code11.

        Default is 6

      • setMinimum1DQuietZoneSize

         Unit setMinimum1DQuietZoneSize(Integer minimum1DQuietZoneSize)

        Minimum quiet zone size on the left and right sides of a 1D barcode, measured in number of modules. The quiet zone is only for 1D barcodes with weak start/stop patterns, i.e. Iata2Of5, Industrial2Of5, Code25, Itf, Codabar, MsiPlessey, and Code11.

        Default is 6

      • setStripCheckDigits

         final Unit setStripCheckDigits(Boolean stripCheckDigits)

        If true, the check digits are stripped from the result.

        Default is false

      • getEan8

         final Boolean getEan8()

        If true, scan and return valid EAN-8 barcodes.

        Default is true

      • setEan8

         final Unit setEan8(Boolean ean8)

        If true, scan and return valid EAN-8 barcodes.

        Default is true

      • getEan13

         final Boolean getEan13()

        If true, scan and return valid EAN-13 barcodes.

        Default is true

      • setEan13

         final Unit setEan13(Boolean ean13)

        If true, scan and return valid EAN-13 barcodes.

        Default is true

      • getUpca

         final Boolean getUpca()

        If true, scan and return valid UPC-A barcodes. If false, but ean13 is true, then UPC-A barcodes will be returned as EAN-13 barcodes.

        Default is true

      • setUpca

         final Unit setUpca(Boolean upca)

        If true, scan and return valid UPC-A barcodes. If false, but ean13 is true, then UPC-A barcodes will be returned as EAN-13 barcodes.

        Default is true

      • getUpce

         final Boolean getUpce()

        If true, scan and return valid UPC-E barcodes.

        Default is true

      • setUpce

         final Unit setUpce(Boolean upce)

        If true, scan and return valid UPC-E barcodes.

        Default is true